Technology
Standards:
IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX,
IEEE802.3ab1000BASE-T, IEEE802.3z 1000BASE-SX/1000BASE-LX,
IEEE802.3x, IEEE802.1p, IEEE802.1Q, IEEE802.1w, IEEE802.1x
Forward and Filtering Rate:
14,880pps for 10Mbps
148,810pps for 100Mbps
1,488,100pps for 1000Mbps
Packet Buffer Memory:
2M bits
Processing Type:
Store-and-Forward
Half-duplex back-pressure and IEEE802.3x full-duplex flow control
Address Table Size:
8192 MAC addresses
Power
Input:
Input Voltage: 12 to 48VDC (Terminal Block); 12VDC (DC Jack)
Power Consumption:
15W Max. 1.25A@12VDC, 0.625A@24VDC
Overload Current Protection:
Present
Reverse Polarity Protection:
Present
Mechanical
Casing:
Aluminum case
IP30
Dimensions:
65mm (W) x 125mm (D) x145mm (H)
(2.56" (W) x 4.92" (D) x 5.71" (H))
Weight:
1Kg (2.2lbs.)
Installation:
DIN-Rail (Top hat type 35mm), Panel Mounting
Interface
Ethernet Port:
10/100BASE-TX: 16, 12 or 8 ports
100BASE-FX: 0, 1, 2 or 4 ports
Gigabit: 0, 1 or 2 ports
Console Port:
Port: One DB9 RS-232 port
LED Indicators:
Per Unit: Power Status (Power 1, Power 2, Power 3)
Per Port: 10/100BASE: Link/Activity
1000BASE: Link/Activity (Green: Copper, Amber: Fiber)
Alarm Contact:
One relay output with current 1A@24VDC
Environment
Operating Temperature:
-40°C to 75°C (-40°F to 167°F)
Tested @ -40°C to 85°C (-40°F to 185°F)
Storage Temperature:
-45°C to 85°C (-49°F to 185°F)
Ambient Relative Humidity:
5% to 95% (non-condensing)
Regulatory Approvals:
ISO:
Manufactured in an ISO9001 facility
Safety:
UL508
Hazardous Locations:
UL1604 (ISA 12.1201)
EMI:
FCC Part 15, Class A
EN61000-6-4
EN55022
EN61000-3-2
EN61000-3-3
EMS:
EN61000-6-2
EN61000-4-2 (ESD Standards)
Contact: + / - 6KV; Criteria B
Air: + / - 8KV; Criteria B
EN61000-4-3 (Radiated RFI Standards)
10V/m, 80 to 1000MHz; 80% AM Criteria A
EN61000-4-4 (Burst Standards)
Signal Ports: + / - 4KV; Criteria B
D.C. Power Ports: + / - 4KV; Criteria B
EN61000-4-5 (Surge Standards)
Signal Ports: + / - 1KV; Line-to-Line; Criteria B
D.C. Power Ports: + / - 0.5KV; Line-to-earth; Criteria B
EN61000-4-6 (Induced RFI Standards)
Signal Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A
D.C. Power Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A
EN61000-4-8 (Magnetic Field Standards)
30A/m @ 50, 60Hz; Criteria A
Environmental Test Compliance:
IEC60068-2-6 Fc (Vibration Resistance)
5g @ 10~150Hz, Amplitude 0.35mm (Operation/Storage/Transport)
IEC60068-2-27 Ea (Shock)
25g @ 11ms (Half-Sine Shock Pulse; Operation)
50g @ 11ms (Half-Sine Shock Pulse; Storage/Transport)
IEC60068-2-32 Ed (Free Fall)
1M (3.281ft.)