Technology
Standards:
IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX/100BASE-FX,
IEEE802.3ab 1000BASE-T, IEEE802.3z 1000BASE-SX/1000BASE-LX,
IEEE802.3x, IEEE802.1p, IEEE802.1Q, IEEE802.1w, IEEE802.1x
Forward and Filtering Rate:
14,880pps for 10Mbps
148,810pps for 100Mbps
1,488,100pps for 1000Mbps
Packet Buffer Memory:
3M bits
Processing Type:
Store-and-Forward
Half-duplex back-pressure and IEEE802.3x full-duplex flow control
Address Table Size:
8192 MAC addresses
Power
Input:
(T) : +/-48VDC(36~75VDC) Internal Universal PSU
(W) : 88~370VDC and 90 ~ 264VAC Internal Universal PSU
(C) : 90~264VAC, 50 ~ 60Hz Internal Universal PSU
Power Consumption:
42.7W Max.
Overload Current Protection:
Present
Mechanical
Casing:
Metal case
IP 30
Dimensions:
Single Power : 442mm (W) x 284mm (D) x 44.2mm (H)
(17.4" (W) x 11.1" (D) x 1.74" (H))
Redundant Power : 442mm (W) x 375mm (D) x 44.2mm (H)
(17.4" (W) x 14.7" (D) x 1.74" (H))
Weight:
3.4Kg (7.5lbs.)
Installation:
Rack Mounting
Interface
Ethernet Port:
10/100BASE-TX: 24, 16, 8 or 0 port
100BASE-FX: 0, 4, 8, 12, 16, 20 or 24 ports
Gigabit: 0, 2 or 4 ports
Console Port:
Port: One DB9 RS-232 port
LED Indicators:
Per Unit: Power Status
Per Port: 10/100TX, 100FX: Link/Activity (Green)
10/100/1000TX, 1000SX/LX: Link/Activity (Green)
SFP Selected: Selected/Unselected (Green)
Environment
Operating Temperature:
-40°C to 75°C (-40°F to 167°F)
Tested @ -40°C to 85°C (-40°F to 185°F)
Storage Temperature:
-45°C to 85°C (-49°F to 185°F)
Ambient Relative Humidity:
5% to 95% (non-condensing)
Regulatory Approvals:
ISO:
Manufactured in an ISO9001 facility
Safety:
UL508
EMI:
FCC Part 15, Class A
EN61000-6-4
EN55022
EN61000-3-2
EN61000-3-3
EMS:
EN61000-6-2
EN61000-4-2 (ESD Standards)
Contact: + / - 8KV; Criteria B
Air: + / - 15KV; Criteria B
EN61000-4-3 (Radiated RFI Standards)
35V/m, 80 to 3G; 80% AM Criteria A
EN61000-4-4 (Burst Standards)
Signal Ports: + / - 4KV; Criteria A
A.C. Power Ports: + / - 4KV; Criteria A
EN61000-4-5 (Surge Standards)
Signal Ports: + / - 2KV; Line-to-Line; Criteria B
A.C. Power Ports: + / - 4KV; Line-to-earth; Criteria A
EN61000-4-6 (Induced RFI Standards)
Signal Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A
A.C. Power Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A
EN61000-4-8 (Magnetic Field Standards)
1000A/m @ 50, 60Hz; Criteria A
Environmental Test Compliance:
IEC60068-2-6 Fc (Vibration Resistance)
5g @ 10~150KHz, Amplitude 0.35mm (Operation/Storage/Transport)
IEC60068-2-27 Ea (Shock)
25g @ 11ms (Half-Sine Shock Pulse; Operation)
50g @ 11ms (Half-Sine Shock Pulse; Storage/Transport)
IEC60068-2-32 Ed (Free Fall)
1M (3.281ft.)