Technology
Standards:
IEEE802.3 10BASE-T, 802.3u 100BASE -TX/FX, 802.3ab 1000BASE-T,
802.3z 1000BASE-SX/LX
IEEE802.3 x Flow Control:Flow control for full-duplex
IEEE802.1p Queue Priority:Support four priority Queues
Forward and Filtering Rate:
14,880pps for 10Mbps
148,810pps for 100Mbps
1,488,100pps for 1000Mbps
Packet Buffer Memory:
1.125M bits
Processing Type:
Store-and-Forward
Half-duplex back-pressure and IEEE802.3x full-duplex flow control
Address Table Size:
8192 MAC addresses
Latency:
64 Bytes packet length less than 2.9μs
1518 Bytes packet length less than 7.9μs
Power
Input:
Input Voltage: 12 to 32VDC (Terminal Block); 12VDC (DC Jack)
Power Consumption:
7.2W Max. 0.6A@12VDC, 0.3A@24VDC
Overload Current Protection:
Present
Reverse Polarity Protection:
Present
Mechanical
Casing:
Aluminum case
IP30
Dimensions:
58mm (W) x 110mm (D) x 135mm (H)
(2.29" (W) x 4.33" (D) x 5.31" (H))
Weight:
0.8Kg (1.761lbs.)
Installation:
DIN-Rail (Top hat type 35mm), Panel Mounting
Interface
Ethernet Port:
Gigabit: 8 ports (2 Fiber combo ports included)
LED Indicators:
Per Unit: Power Status (Power 1, Power 2, Power 3)
Per Port: Link/Activity (Green:10/100Mbps, Orange:1000Mbps)
Alarm Contact:
One relay output with current 1A@24VDC
Environment
Operating Temperature:
-20°C to 60°C (-4°F to 140°F)
Tested @ -30°C to 70°C (-22°F to 158°F)
Storage Temperature:
-40°C to 85°C (-40°F to 185°F)
Ambient Relative Humidity:
5% to 95% (non-condensing)
Regulatory Approvals:
ISO:
Manufactured in an ISO9001 facility
Safety:
UL508
EMI:
FCC Part 15, Class A
EN61000-6-3
EN55022
EN61000-3-2
EN61000-3-3
EMS:
EN61000-6-2
EN61000-4-2 (ESD Standards)
Contact: + / - 4KV; Criteria B
Air: + / - 8KV; Criteria B
EN61000-4-3 (Radiated RFI Standards)
10V/m, 80 to 1000MHz; 80% AM Criteria A
3V/m, 1400 to 2000MHz; 80% AM Criteria A
1V/m, 2000 to 2700MHz; 80% AM Criteria A
EN61000-4-4 (Burst Standards)
Signal Ports: + / - 4KV; Criteria B
D.C. Power Ports: + / - 4KV; Criteria B
EN61000-4-5 (Surge Standards)
Signal Ports: + / - 1KV; Line-to-Line; Criteria B
D.C. Power Ports: + / - 0.5KV; Line-to-earth; Criteria B
EN61000-4-6 (Induced RFI Standards)
Signal Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A
D.C. Power Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A
EN61000-4-8 (Magnetic Field Standards)
30A/m @ 50, 60Hz; Criteria A
Environmental Test Compliance:
IEC60068-2-6 Fc (Vibration Resistance)
5g @ 10~150Hz, Amplitude 0.35mm (Operation/Storage/Transport)
IEC60068-2-27 Ea (Shock)
25g @ 11ms (Half-Sine Shock Pulse; Operation)
50g @ 11ms (Half-Sine Shock Pulse; Storage/Transport)
IEC60068-2-32 Ed (Free Fall)
1M (3.281ft.)